To analyze and solve the static troubles without measuring the charge is very complicated. So utilization of static meter will be a good decision for technical personnel to solve troubles caused by static electricity. Static meter shows amplitude and polarity of static electricit
y and where and how it was generated. It is quick to expose positive and negative loads up to 160.000 Volts. If to solve trouble the static eliminator is needed, static meter will rate the most appropriate position for static eliminator and show its performance. Static meter forms standards due to that would be solved future static troubles and enhanced work of technical personnel. These standards are varied from charging level of dangerous areas to charging level of ordered, produced or sent to client product. Its accuracy, stability of easement in use and convenient size of device make Puls static meter an ideal instrument for engineers.
General Specification
- Rapid and simple in use
- Compact design
- LCD display
Technical Specifications
Measurement Range | 0-160 kV Full Scale | ||
Resolution | 100 V | ||
Drift | Less than 1% | ||
Accuracy | Better than +/-5% | ||
Display | 31/2 Digit, LCD Display and low battery indication | ||
Control | Push Button | ||
Power Supply | 9 Volt Replaceable Battery | ||
Dimensions | 150 x 66 x 32 mm | ||
Accessory | Case, protective strap,operating instruction |
Application
Sleeving Machines Application Sheet
On automated sleeving machines, the problems arise as the sleeve is opened for fitting to the bottle. As the sleeve is opened, the two surfaces are separated and electrons migrate from one surface to another. As the material is Non conductive, it cannot re-address the imbalance and retains the static charge.
The charged labels will now become attracted to an earth potential or a charge of the opposite polarity. If the bottle the label is being fitted to is of the same polarity, the label will repel and jam causing waste and rejects. If the bottle is of the opposite polarity, the label will be attracted to bottle too quickly and the syncronisation will be out, causing jams, down time and waste.
By neutralising the bottles prior to the label being fitted, you will eliminate the chance of material misbehavior and miss aligning. This will reduce waste and rejects and increase volume, productivity and profits.
About Static Electricity
Static electricity refers to the build-up of electric charge on the surface of materials. Materials are made of atoms and normally are electrically neutral by having an equal number of positive and negative charges (proton and electron).
The phenomenon of static electricity occurs when the negative and positive ions imbalance has place to be. This imbalance happens when two materials (atoms) being in contact gain or lose electrons which may move easily between them. Electrons leave an excess of positive charge on one material, and an equal negative charge on the other. When the materials are separated they retain this charge imbalance.
The static charges remain on an object until they either bleed off to ground or are quickly neutralized by a discharge.
Static Measuring
SF 156 Static Meter
The utilization Static Meter is a good solution for technical personnel to analyze and solve troubles caused by static electricity.
Charging Bonding
Static Charging Generator 20, 30, 60, 100, 120 kV
Static Charging Generator is high voltage supplier for neutralizers (anti static devices) working at direct current (DC)
Static Charging Bar
Charging Bar device utilization helps to stick materials to any surface or to each other by static electricity without any glueing substance.
Perforation Detector
Perforation Detector is used to detect perforation on any material in packaging industry or to count the bag numbers by detecting and reporting the perforation in bag making machinery.
IML Foam
IML Foam is used as an electrifiable material on the front face of static loading apparatuses and may stand high voltage.
5 Pin IML Head
5 PIN IML Head is a perfect solution to make tags get glued to mould carefully in in-mould applications.
DC High Voltage Distributor
High voltage distributoris designed to make easy connection in high voltage applications working at direct current (DC)
Static Elimination
KDA 75 Anti Static Bar
KDA 75 Anti Static Bar is a good choice to remove static electricity. It can be used even in high-speed applications.
Anti static Air Gun
Anti static Air Gun is a hand-held ionizing air gun for neutralization static charge and removing dust contamination of industrial applications.
GK75/A02 Power Supply
GK75/A02 Power Supply is used as a high voltage generator designed for devices of one or two-fan ionizing air blowers.
GK75A Power Supply
GK75A Power Supply is used as high voltage generator designed for devices of active ionization.
100HZ Power Supply
100HZ Power Supply is used in fast running machines as supplier for tandem work of two ionizing bars.
Single Anti Static Blower
Single anti static blower with one fan is designed to neutralize the static charges over a large area by supplying enough ionized air flow.
Dual Anti Static Blower
Dual anti static blower with coupled fan is designed to neutralize the static charges over a large area by supplying enough ionized air flow.
Static Control Nozzles
Static control nozzles are designed to neutralize high static charge in those industrial applications where anti static bar cannot be mounted. They are simple, soft and efficient in its use.
Blower Driven Air Boost Bar
Blower driven anti static bar is connected to air apparatus designed to neutralize the static charges at large distances. It provides high performance and efficient ionization with fast discharging time.
Compressed Driven Air Boost Bar
Compressed Driven Air Boost Bar is connected to air apparatus designed to neutralize the static charges at large distances. It provides high performance and efficient ionization with fast discharging time.
AC High Voltage Distributor
High voltage distributor is designed to make easy connection in high voltage applications working at alternating current (AC)